DuraVent - DirectVent Pro 4"x6" Diameter  Wall Thimble  3" Top Clearance

Introducing the DuraVent DirectVent Pro 4"x6" Diameter Wall Thimble with a 3" Top Clearance – the perfect solution for your venting needs! Designed with exceptional quality and advanced features, this wall thimble offers unparalleled performance and safety for your direct venting system.

With a 4"x6" diameter, this wall thimble is specifically engineered to accommodate the demands of direct vent installations. It seamlessly connects your vent pipe to the exterior wall, ensuring a secure and efficient passage for exhaust gases. The durable construction of the DuraVent DirectVent Pro guarantees long-lasting reliability, making it an ideal choice for both residential and commercial applications.

One of the standout features of this wall thimble is its 3" top clearance, providing ample space for proper venting. This clearance ensures proper air circulation and minimizes the risk of overheating or damage to the surrounding materials. You can have peace of mind knowing that the DuraVent DirectVent Pro prioritizes safety and adheres to the highest industry standards.

Installation is a breeze with the DuraVent DirectVent Pro Wall Thimble. It is designed to be user-friendly, allowing for quick and straightforward assembly. The precise engineering and tight seals of this thimble guarantee a leak-free connection, preventing any unwanted drafts or gas leakage.

This wall thimble is part of the DirectVent Pro series, renowned for its compatibility and versatility. It is compatible with other components of the DirectVent Pro line, offering you the flexibility to create a comprehensive venting system tailored to your specific needs.

Typical Installations(Refer this if required):

Refer to our Typical Venting Installation drawings to select the appropriate component parts for your installation.

Top

Planning Your Installation:

1 For vertical gas stove installations, measure the height from the stove outlet to the ceiling to determine the length of black pipe required. Select a ceiling support/wall thimble cover or a cathedral ceiling support box.
2 To determine the length of galvanized pipe required, measure the ceiling thickness and the vertical rise in an attic or second story. Firestops are required at each floor level beyond the first floor ceiling support/wall thimble cover or cathedral ceiling support box. If an offset is required to avoid obstructions, use a pair of 45° elbows. For proper support, use elbow straps with offsets. Use wall straps for long vertical runs. Attic Insulation Shield is required in attic.
3 Measure the roof pitch. Select the proper flashing and storm collar. Determine the minimum height above the roof.
4 For horizontal installations, check the appliance manufacturer’s instructions for minimum rise and maximum horizontal run. A snorkel termination may be used if height restrictions prevent adequate rise above the appliance. Select the appropriate Horizontal Termination Cap (see appliance manufacturer installation instructions). To protect vinyl siding, select vinyl siding standoff. Check appliance manufacturer’s instructions for wall thimble and firestop requirements.

Design Recommendations

  • The following design recommendations are general guideline to assist in the design and selection of venting components for your installation. Always follow DuraVent Installation instructions enclosed with the cap or support box before installing your chimney system. Installation instructions can be viewed online at www.duravent.com, under Catalogs and Instructions. Important: Check the manufacturer’s rating plate and instruction manual to confirm that the DuraVent direct vent system is approved for use on the brand name appliance you have selected.
  • The inner and outer pipe diameters should match the outlet size of the appliance.
  • Check the appliance manufacturer’s installation instructions to confirm which types of vent configurations are permitted (i.e. horizontal, vertical, chimney reline, etc.). Also, check for any venting restrictions such as maximum horizontal run, minimum and maximum vertical rise, maximum offset, etc.
  • Be fire safe! Maintain at least the minimum clearances (air-space) between the vent pipe and nearby combustibles, as specified in the appliance manufacturer’s installation instructions. Use proper support and bracing. Follow local building codes and have your venting system inspected.

 

 